AlkoFor S40 Breathalyzer
Delivery and payment
Choose your city or town to see the price with delivery there and when you can get it.
Pickup points
- Branch
- Parcel locker
Pros
- Up to 12 tests per minute
- Selective electrochemical sensor
- Hygienic, contactless breath sampling
- Signals for access control systems and turnstiles
- Adjustable threshold from 0.1–0.9‰
Cons
- Requires a stable 12 V power supply
- No memory for test results
- Annual calibration is mandatory
What is the AlkoFor S40 and why use it at an entrance checkpoint?
The AlkoFor S40 is a stationary, contactless breathalyzer with an electrochemical sensor, designed for high-volume screening at factory and warehouse entrances, motor pools, depots, and workplaces that conduct pre-trip checks. Its purpose is simple: quickly identify people who should not start their shift today, and certainly should not operate equipment.
The device is designed to integrate with access control systems. Based on the test result, it indicates “ACCESS GRANTED” or “ACCESS DENIED” using lights, sounds, and control signals for a turnstile or lock.
How the test works: contactless, fast, and resistant to cheating
The test is contactless: the person blows steadily into the sampling opening for approximately 2 seconds from a distance of about 5 cm, much like blowing out a candle. The device checks whether the breath sample is valid. If the breath is weak or intermittent, or an attempted imitation does not resemble a real breath, the status indicator will show an error and the test must be repeated.
The indicators are straightforward: green “ACCESS GRANTED” means entry is allowed; red “ACCESS DENIED” means access is blocked. A separate “STATUS” indicator shows whether the device is ready, preparing, or analyzing.
Throughput and speed: built for a steady flow of people
The AlkoFor S40 is designed for lines at checkpoints, with a stated throughput of up to 12 tests per minute. It is ready for the first test in approximately 5 seconds, depending on conditions and previous tests. A zero (clean) analysis usually takes about 3 seconds, while a sample containing alcohol vapor may take longer, up to ~60 seconds.
Access control integration: “ACCESS GRANTED/ACCESS DENIED” signals, plus RS-232
This is where things get interesting for engineers and security teams. The S40 can operate in Normal mode (controlled by analog signals) or PC mode (controlled through a COM port). The COM port uses RS-232 and is suitable for integration with control terminals, turnstiles, and security systems. Commands and examples are usually provided in the documentation or by the service center.
In Normal mode, the device has a set of signal lines in the cable, including:
- “ACCESS GRANTED”: +12 V output for approximately 0.5 s (via relay)
- “ACCESS DENIED”: +12 V output for approximately 0.5 s (via relay)
- Device ready/not ready signal
- “Device on” signal
- “Result issued” signal
- Lockout input to temporarily stop operation
A practical note: the “ACCESS GRANTED/ACCESS DENIED” outputs supply voltage through relays, with a recommended load of up to 1 A depending on the power supply. The other lines are signal lines for direct connection to a controller and should not be used as power outputs.
Power, installation, and hardware
Power supply: 12 V DC, 1.5 A. For stable operation, use a suitable power supply with minimal ripple, as specified in the documentation, and keep the voltage above the minimum operating level.
The housing is designed for stationary wall or panel installation and comes with mounting plates. Its IP54 rating provides protection against dust and splashes, but it is not intended for direct water exposure or aggressive environments.
Another useful configuration option is to order the device with an additional wiring kit and switch, plus an external power supply, for operation without an access control system. Essentially, you can install it, switch it on, and start testing.
Accuracy, thresholds, and metrology (no magic, just procedures)
The AlkoFor S40 uses an electrochemical sensor to measure ethyl alcohol vapor in exhaled air and displays the result in ‰ (per mille). The user can adjust the trigger threshold from 0.1–0.9‰. The factory or typical setting may depend on the batch configuration or company policy.
Important: the device is not a medical device. The instructions also explicitly warn against using the breathalyzer as permission to drink and drive.
For legally significant use, two things are critical: proper operation and timely servicing, including calibration and verification. The usual schedule is once every 12 months.
Hygiene and maintenance: no alcohol, seriously
Because the test is contactless, disinfection after each person is not required. However, there is one strict rule: do not clean the device with alcohol-containing products, as they can damage the sensor. Use alcohol-free wipes or disinfectants to clean it; the funnel can be removed, rinsed with water, and dried.
The sensor module is replaceable. After replacement, if the device is used in a legally regulated metrology setting, an additional verification or calibration at an authorized service center may be required.
Who it is for (and who it is not)
A good fit if you need to quickly screen people entering a facility, with automation through a turnstile, electric lock, or access control system and minimal human intervention.
Not a good fit if you want to keep a measurement log in the device’s own memory, which it does not have, or expect a device for home use. This is a workplace tool for discipline and safety, not a gadget for entertainment.
Documentation (useful for procurement and integration)
Before installation and connection, consult the official documentation and wiring diagrams: the AlkoFor S40 product page and the user manual (PDF).