Sentech AL7M Replaceable Sensor for AlcoScan AL-7000 Breathalyzer
Delivery and payment
Choose your city or town to see the price with delivery there and when you can get it.
Pickup points
- Branch
- Parcel locker
Pros
- Quick replacement without a service visit
- Pre-calibrated module
- Restores like-new accuracy
- Original format for the AL-7000
- Compact and sealed in its packaging
Cons
- Service life needs to be monitored
- Sensitive to smoke and moisture
- Incompatible with other models
What is the AL7M and why do you need it?
The AL7M is a replaceable sensor module for the Alcoscan AL-7000 breathalyzer. The idea is simple: instead of having the device calibrated at a service center, you simply replace the module, and the breathalyzer works as if it had just been calibrated.
The AL7M (‰) version is typically associated with per mille (‰) readings on compatible AL-7000 devices. If your AL-7000 uses different units or is a different revision, check the markings on the old module and the connector type before buying.

When the module is ready to retire
Breathalyzer sensors don't last forever. For the AL-7000, the typical recommendation is to replace the module after approximately 200–300 tests (or about 1 year of use, depending on conditions and frequency).
Practical signs that it's time to replace the module:
- readings fluctuate for no apparent reason;
- the breathalyzer asks you to repeat the breath test more often;
- results are suspiciously high or low;
- you know you've run a lot of tests and haven't been keeping count.
Compatibility: an important note about AL-7000 versions
There are different revisions of the AL-7000 on the market. Some older and newer variants use different module interfaces. A common clue is that a compatible sensor or connector may have 2 rows of contacts rather than 1, and there may be a printed black (or sometimes white) ring around the metal part of the module.
The most reliable check is to look at your old module: the markings and connector shape should match.
How to replace the AL7M sensor: quick and hassle-free
The module is designed to be replaced by the user, but take care when doing so:
- Turn off the breathalyzer.
- Remove the batteries (this is important).
- Open the compartment cover marked SENSOR on the back.
- Remove the old module and fit the new AL7M securely in place.
- Close the cover, reinstall the batteries, and run a test.
For official instructions and videos, visit the manufacturer's resource page: Alcoscan User Manual.
Storage and handling: protecting your new sensor
The sensor module comes in a sealed foil pouch for a reason. Follow these simple rules to help its service life stay closer to 300 tests than 300 seconds:
- Keep the module in its packaging until installation.
- Recommended storage temperature: 10–24 °C.
- Keep smoke, saliva, moisture, and other contaminants out of the sensor.
- Avoid extreme temperatures during storage and transportation.
Another useful habit is to wait at least 20 minutes after eating or drinking before testing, especially after alcohol, mouthwash, or anything with a strong aroma. This reduces the chance of false readings caused by residual alcohol in the mouth.
Who is it for?
The AL7M replacement sensor is a must-have if the AL-7000 is used regularly, whether for home checks, at a business, on board a vessel, or in any situation involving frequent tests. A single module effectively restores accuracy without sending the device in for service or experiencing downtime.
A common-sense reminder: a breathalyzer is a useful self-monitoring tool, but it does not replace official methods or procedures where regulated measurements are required.