Крамниця

FLUS ET-921

In stock ET921
3 599 ₴

Delivery and payment

Choose your city or town to see the price with delivery there and when you can get it.

Pickup points

  • Branch
  • Parcel locker

Pros

  • Wide range up to ±34.47 kPa
  • 11 measurement units
  • MAX, MIN and average values
  • Backlight and data hold
  • Case and tubes included

Cons

  • No data transfer to a PC
  • Runs on a 9V battery
  • Accuracy is based on the full scale

FLUS ET-921: when the pressure difference matters

The FLUS ET-921 is a compact digital differential manometer. Rather than measuring pressure in isolation, it compares readings at two connected points and displays the difference between them. That makes it useful for checking ventilation, filters, air ducts, air conditioners and cleanrooms, as well as troubleshooting low-pressure gas systems.

The measurement range is ±34.47 kPa, or ±0.344 bar. That provides plenty of range for diagnosing air systems: the instrument is equally suited to measuring a small pressure drop across a filter or checking a more substantial pressure difference between two points in a circuit.

FLUS ET-921 differential manometer held in a hand with tubes connected

Accuracy and range

The ET-921 measures pressure with a resolution of 0.01 kPa and a stated accuracy of ±0.3% of full scale at 25 °C. An important detail: accuracy is based on the full scale, not the current reading. For very small pressure differences, take care with zeroing and measurement conditions. The instrument is reliable, but no button can override the laws of physics.

Users can switch between 11 units: kPa, bar, mbar, mmHg, centimeters and meters of water column, as well as common imperial units. This is convenient when equipment documentation gives readings in units other than kilopascals.

Easy connections

Two metal fittings for the tubes are located at the top of the housing. Connect the tubes to the two points you want to compare, and the pressure difference appears immediately on the large LCD. The maximum allowable input pressure is 137.9 kPa: the ET-921 is designed for diagnosing air and gas circuits, not for experimenting with high pressure.

Before taking precise measurements, manually zero the instrument with the tubes disconnected by holding the HOLD button for about three seconds. This simple step saves you from wondering, “Why is it already showing a reading when I haven't connected anything?”

Features for practical diagnostics

Five buttons cover the main operating functions: power, backlight, unit selection, data hold and recording results. REC mode displays the maximum, minimum and average values, as well as the measurement time. This is useful when pressure fluctuates and a single glance at the display isn't enough.

The backlight makes work easier in equipment cabinets, above ceilings or in dark ventilation ducts. The instrument also indicates a low battery and signals readings outside the measurement range with ERR1 or ERR2 codes. Auto power-off after about 25 minutes of inactivity saves battery power and can be disabled if needed.

Power and package contents

The FLUS ET-921 runs on one 9V 6F22 battery. It installs under the rear cover without tools. The unit weighs about 122 g and measures 15.5 × 6.2 × 3 cm, so the manometer won't weigh down a technician's bag and fits easily into the included case.

The box contains the manometer, a battery, flexible and rigid tubes, two fittings, a case and a manual. For a basic ventilation check or a pressure drop measurement across a filter, you won't have to immediately go looking for small accessories.

Conclusion

The FLUS ET-921 is a straightforward working tool for ventilation, air conditioning, filtration and service diagnostics professionals. It doesn't try to be a laboratory in your pocket: there is no wireless connectivity or log export to a computer. What it does offer is a wide range, sufficient accuracy for technical tasks, 11 units, zeroing, a backlight and a ready-to-use kit. It's a practical choice when you need to measure a pressure difference quickly without the hassle of an analog scale.

Air, Gases
-34.47—34.47 kPa
137.90 kPa
-34.47—34.47 kPa
0.30 %
0.01 kPa
0.30 %
25 °C
0.25 %
0.10 %
137.90 kPa
11
kPa, bar, mbar, mmHg, cm H₂O, ftH₂O, kgf/cm², psi, inHg, inH₂O, oz/in²
11
Manual
Air, Gases
Device
0—40 °C
-10—60 °C
0—90 %
LCD
Yes
30 × 155 × 62 mm
122 g
No
Minimum value, Maximum value, Average value, Elapsed time
Yes
Data hold, Maximum value, Minimum value, Average value, Zeroing, Out-of-range indication
Overrange warning, Error codes
Yes
Yes
Replaceable batteries
9V
1
2
Barbed hose fitting
4.50 mm
Metal fittings, Positive (+) port, Negative (-) port
4.50 mm
3.18 mm

Compare with similar products