Pros

  • Wide range up to ±206.8 kPa
  • 11 pressure measurement units
  • Max, Min, Avg and Hold
  • Backlight and auto power-off
  • Case, tubing and adapters

Cons

  • Powered only by a 9 V battery
  • Does not replace a data logger
  • Requires airtight connections

FLUS ET-923: turn “there's a draft somewhere” into a precise number

The FLUS ET-923 is a portable digital differential manometer for measuring positive or negative pressure differences in gases. Simply put, it compares the pressure at two points: for example, before and after a filter, on opposite sides of a fan, or in an air duct, a pressurized chamber or a pneumatic system. The result appears on the screen immediately, with no U-shaped tubes, colored liquid or guesswork over the meniscus.

The device is a practical tool for professionals working in ventilation, air conditioning, air filtration, pneumatic system setup, gas equipment servicing and laboratory testing. The two ports on top mark the measurement points: pressure at the “+” inlet is compared with pressure at the “−” inlet. Swapping the tubes changes only the sign of the reading, which is useful when you need to quickly determine the direction of the pressure difference.

FLUS ET-923 differential manometer with tubing connected

A range for substantial pressure differences

The ET-923's primary scale covers a differential from −206.8 to +206.8 kPa with a resolution of 0.1 kPa. That's equivalent to ±2.068 bar or ±30 psi, so the device isn't limited to delicate draft checks in ventilation ducts: its range is also sufficient for systems with substantial pressure.

For fine balancing of very small pressure differences, however, the resolution is worth considering. The ET-923 is designed primarily as a versatile instrument with a wide range, not as an ultra-precise micromanometer for measurements in single pascals. Its capabilities are more than sufficient for checking filter clogging and the operation of exhaust systems, pumps, compressors or pneumatic circuits.

The product name may include the value “±2608 mbar,” but this is inconsistent with the device's other scales. The ±206.8 kPa limit corresponds to ±2068 mbar, so use that value when making your selection.

11 units, no pocket calculator needed

The UNITS button cycles through 11 measurement units: kPa, mbar, bar, psi, mmHg, inches of mercury, centimeters and feet of water column, inches of water column, kgf/cm² and oz/in². This is especially convenient during service work: there's no need to convert values manually when ventilation system documentation uses mm of water column and the compressor specification uses psi.

The stated accuracy is ±0.3% of full scale at 25 °C. The device also tracks maximum, minimum and average values, displays relative measurement time and lets you freeze the current reading with the HOLD button. This is handy when you can no longer see the screen because your hands are occupied with tubing, an access hatch or another surprise in the equipment room.

Front panel of the FLUS ET-923 digital differential manometer

Ready for field work

The FLUS ET-923 weighs about 212 g and measures 172 × 77 × 37 mm, making it easy to hold in one hand and carry in a service bag. The large LCD has a backlight, so readings are easy to see in a ventilation room, near a ceiling or beside equipment with less-than-friendly lighting.

In addition to the backlight, the device offers zeroing, offset compensation, a low battery indicator and auto power-off. If a measurement goes out of range, it displays an error code instead of trying to invent a convincing number. It runs on a standard 9 V 6F22 battery, which is easy to find, though it's worth keeping a spare for regular work.

Connections and what's included

Two quick-release ports with a diameter of 3.18 mm accept tubing for simultaneous monitoring of two points. The package includes tubing, adapters, a soft carrying case and instructions. This kit lets you start measuring almost immediately, although specific systems may require additional adapters for a particular port or thread.

The accuracy of any differential manometer depends not only on the sensor but also on the airtightness of the entire setup. Before measuring, check the tubing for cracks, fit it securely onto the ports and zero the device with equal pressure at both inlets.

Conclusion

The FLUS ET-923 is a straightforward working tool for measuring pressure differences in gas systems. Its strengths include a wide range, 11 scales, quick readings, Max/Min/Avg statistics and a connection kit. It's a good choice for diagnosing ventilation, filtration, pneumatic systems and equipment where the pressure difference matters.

It is not, however, a gas analyzer or a leak detector, nor is it suitable for use in explosive atmospheres without separate confirmation of compliance. Its job is simple and important: to show accurately how much the pressure at one point differs from the pressure at another.

Gases, Air
-206.80—206.80 kPa
0.10 kPa
0.30 %
25 °C
0.25 %
0.10 %
689.50 kPa
inH₂O, psi, mbar, kPa, inHg, mmHg, oz/in², ftH₂O, cm H₂O, kgf/cm², bar
11
Device
Ventilation, Air conditioning, Air filtration, Pneumatic systems, Gas systems
0—40 °C
-10—60 °C
LCD
Yes
37 × 77 × 172 mm
212 g
Yes
Yes
Replaceable batteries
9V
1
0.50 s
Maximum value, Minimum value, Average value, Data hold, Zeroing, Offset compensation, Out-of-range indication, Data compensation
2
Quick-release
3.18 mm