Flus ET-965
Delivery and payment
Choose your city or town to see the price with delivery there and when you can get it.
Pickup points
- Branch
- Parcel locker
Pros
- 5 measurements in one
- Remote sensors included
- Backlit display
- HOLD and MAX/MIN
- Tripod mount
Cons
- Humidity: moderate accuracy
- Sound level meter is not for certification
- Powered by a 9V battery
FLUS ET-965: a “multitool” for indoor climate and working conditions
The FLUS ET-965 is a compact “5-in-1” measuring instrument that measures five things: sound level, illuminance, air speed, temperature, and relative humidity. It lets you take one instrument into the field instead of three to five separate ones, without feeling like a walking warehouse.

What's included and design: why it's convenient in the field
The ET-965's key feature is its remote sensors. You can hold the display unit in your hand or put it on a tripod, and position the sensor where you need to take a reading:
- vane anemometer for air speed;
- light sensor for lux (and Fc when needed);
- temperature/humidity sensor for indoor climate;
- microphone with a windscreen for sound (important in drafts or outdoors).
The housing has a tripod mount and a 9 V external power jack, useful for long measuring sessions when you don't want to drain the battery during a shift.
Controls: straightforward buttons
The ET-965 is designed so you don't have to hunt for the right switch in the field:
- MODE cycles through modes: sound → air speed → illuminance.
- A separate button switches Temperature / Humidity on the upper part of the display.
- UNIT changes units in the current mode (for example, m/s ↔ km/h for the anemometer; Lux ↔ Fc for light).
- HOLD freezes the reading.
- MAX/MIN displays the maximum/minimum value for the session.
- Backlight is switched on with a separate button and turns off automatically after approximately 30 seconds of inactivity.
Readings update once per second, so the instrument responds quickly without jumpy readings.
Accuracy: where the ET-965 excels and where it's simply good enough
This feels like a practical instrument for checking ventilation, workplace lighting, indoor sound levels, and conditions in a classroom, office, or workshop, or for carrying out a quick on-site audit.
One important point: the sound level meter meets Class 2 (IEC 61672-1). That's suitable for engineering measurements and monitoring, but legally significant reports or certifications usually call for Class 1 and appropriate verification or calibration.
The same goes for humidity: ±5%RH is fine for monitoring indoor climate, such as checking whether a heat recovery ventilator is drying out the air or a warehouse has condensation, but not for exacting laboratory work.
Practical tips for more accurate readings
- For sound, keep the microphone approximately 1–1.5 m from the source and use the windscreen in drafts or outdoors.
- For air speed, point the anemometer vane directly into the airflow and allow 2–5 seconds for the reading to settle.
- For light, don't shade the sensor with your hand or the housing, and orient it toward the source or measurement plane.
- Give temperature and humidity readings a little time to stabilize after taking the instrument out of a pocket or bag, especially in winter.
- For long sessions, it's more convenient to use an external 9 V power supply and keep the battery as a backup.
The recommended recalibration interval is 1 year, especially if the instrument is used regularly or you spend a lot of time on construction sites.
Who should buy it
The FLUS ET-965 is a good fit for HVAC and ventilation engineers, energy auditors, occupational safety professionals, school and office technical staff, and anyone who needs versatile monitoring of indoor and outdoor conditions without a collection of separate instruments.
It's not intended for acoustic laboratories or tasks requiring the highest sound accuracy or certification classes, or highly accurate humidity measurements for industrial processes.