Крамниця

SARAD RPM 2200 Radon and Thoron Progeny Monitor

In stock
Price on request

Pros

  • Radon and thoron EEC/PAEC
  • Alpha spectrum for each measurement
  • Stable flow rate of 3 L/min
  • Over 100 hours of battery life
  • Optional NaI gamma probe

Cons

  • Heavy: approximately 6 kg
  • Response time up to 120 min
  • Not ATEX-rated for explosive environments

What is the RPM 2200 and why would you need one?

The RPM 2200 is a professional monitor for decay products of radon (Rn-222) and thoron (Rn-220). Rather than simply detecting radon, it measures what actually delivers the dose: short-lived progeny that attach to aerosols and settle in the respiratory tract.

Results are presented in two practical quantities: EEC (equilibrium equivalent concentration) and PAEC (potential alpha energy concentration), separately for radon and thoron. That gives you a ready-to-use result for assessing exposure indoors, in workplaces, and at monitoring stations.

How it works: no magic, just alpha spectrometry

Air is pumped through a membrane filter (1 µm pores). Aerosol particles with attached decay products accumulate on the filter, and a 400 mm² silicon detector records the alpha spectrum (0–10 MeV).

The RPM 2200 does more than count everything together. It has enough spectrometric resolution to separate the contributions of individual progeny, which is critical when you need to distinguish the radon decay chain from the thoron decay chain without guesswork.

Time resolution and thoron: a tricky customer

The stated response time for radon progeny is approximately 120 min. That is normal for instruments in this class: obtaining meaningful statistics takes time and a stable flow rate.

Thoron is more complicated. Because of its decay chain, the RPM 2200 uses an algorithm that differentiates Po-212 activity over time to achieve acceptable time resolution. Otherwise, a reliable thoron measurement could take a very long time. In practice, integration intervals of around 1–3 hours offer a reasonable compromise for thoron.

Operation: pump, filter, and taking care of the pump

Inside is a processor-controlled rotary vane pump that maintains a constant flow rate of 3 L/min. The instrument also accounts for the fact that filters need replacing: it includes filter condition monitoring and an indicator, plus pump overload protection. Running with a clogged filter is a direct route to accelerated wear.

Filter replacement is designed for field use: no special tools are needed, and the mechanism is straightforward. There is no need to remove 6 screws, lose 2, and get frustrated.

Data, memory, connectivity, and long measurements

The RPM 2200 is designed for extended measurement runs: data is recorded to a 2 GB SD card, the instrument is operated via a touchscreen, and a PC connects via USB and RS-232. Remote data transmission and control are also supported, depending on the equipment and modules supplied.

Measurement setup is more flexible than one button for one mode: you can store up to 16 cycles with up to 32 steps, at intervals ranging from 1 second to weeks. This is useful when combining warm-up or stabilization, different sampling modes, nighttime and daytime profiles, and more.

Options: when you need more than radon

If you need all-in-one monitoring, the RPM 2200 can be expanded. The most notable option is an optional NaI(Tl) 2″×2″ gamma probe for dose rate assessment and spectrometry, within the capabilities of NaI. Additional sensors for weather, gas analysis, water analysis, and process monitoring, as well as GPS logging, are also available depending on the configuration.

Who it's for and who it's not

A good fit: laboratories, radiation monitoring services, industrial and construction monitoring contractors, researchers, particularly where the thoron contribution matters, and facilities with logging and repeatability requirements.

Not a good fit: someone who just wants to check a basement once a year. That is like buying a microscope to read the fine print on a contract. It will work, but you may find yourself wondering why.

Useful official resources

If you need primary sources for specifications or procurement: RPM 2200 datasheet (PDF) and RTM/RPM 22xx manual (PDF).

Rn-222, Rn-220
0—1000000
1000—1000
120—120 min
Po212 time differentiation
EEC, PAEC
0—10 MeV
Si detector, Implanted Si
1
4 cm²
Radon, Radon progeny (RDP)
EEC, PAEC
As specified in datasheet
Bq/m³
3 l/min
Membrane filter
1 µm
25.40 mm
EEC, PAEC
Bq per m3
Device
0—40 °C
0—95 %
80—110 kPa
Professional monitor
Radon, Radon progeny (RDP)
Semiconductor
120—120 min
Touch
255 × 235 × 140 mm
6000 g
Yes
60—90 mm
Rechargeable battery, Mains power, Car 12V
100 h
Built-in
1
12 V
NiMH
100—240 V
50—60 Hz
1.80 A
Yes
16
32
SD card
2 GB
Alpha spectra, Time distributions
dVISION, dCONFIG, dLIBRARY
dVISION, dCONFIG, dLIBRARY
USB, RS-232
No
pumped
Yes
Rotary vane
3 l/min
0—4 l/min
5 %
Fixed front panel
Meteo sensors
-20—40 °C
0.50 °C
0—100 %
2 %
80—120 kPa
supported, Remote control
Yes
KML, GIS compatible
Analog inputs, Counter inputs, Status inputs, Switched outputs, Timer output, PID output
Gas analysis, Water analysis, Meteo sensors
Yes
NaI Tl
0.03—3 MeV
7.50 %
5—10 m
Diameter specified, Length specified
How to choose? See our “Radon and thoron monitors” buying guide →

Compare with similar products